MIL-P-53065(ME)
grade B, class I. The plates shall be attached to the pumping unit by screws,
rivets, or bolts in a place where the plate will be visible and legible but not
interfere with the operation and maintenance of the pumping unit.
3.15 Lubrication. The pumping unit shall incorporate bearings of the sealed
pre-lubricated types.
3.16 Electromagnetic interference. Unless otherwise specified (see 6.2). the
pumping unit shall be equipped for the suppression of electromagnetic
interference in accordance with MIL-STD-461 for other than engine-driven
equipment.
3.17 Treatment and painting. The portions of the pumping unit normally
painted internally and externally shall be cleaned, treated, and painted in
accordance with MIL-T-704, type F or G, as applicable. Unless otherwise
specified (see 6.2), the top coat color shall be camouflage green 383 conforming
to MIL-C-46168.
3.18 Fungus and moisture resistance. The electrical circuitry, including all
components and connections, except as specified below, shall be protected from
the effects of fungus growth and moisture by an overall treatment with a varnish
conforming to MIL-V-173, composition I or II, as applicable (see 3.18.1), with
one percent copper 8-quinolinolate (by weight) based on the non-volatile content
of the varnish.
a.
Components or circuit elements that are inherently fungus and moisture
resistant or which are hermetically sealed need not be treated,
b.
Components or circuit elements whose functions will be adversely affected
by the varnish coating shall not be treated.
The varnish shall be applied by spray, brush, or a combination of both to give a
dry-film thickness of not less than 1 mil to component or element surfaces
previously cleaned and prepared so that the surfaces are free from all foreign
matter which would interfere with the adherence or function of the varnish.
3.18.1 Composition. Composition II shall be used only in the case when local
air pollution regulations governing the application of varnish precludes the use
of composition I. When composition II is used, the contractor shall provide
evidence to the Government that the use of composition 11 is required, and shall
certify that the composition 11 material complies with Rule 422, South Coast Air
Quality Management District.
3.19 Workmanship.
3.19.1 Fabrication. Metal used in the fabrication shall be free from kinks,
sharp bends, and other conditions which would be deleterious to the finished
product. Manufacturing processes shall not reduce the strength of the materials
to a value less than intended by the design. Manufacturing processes shall be
done neatly and accurately. All bends shall be made by controlled means to
ensure uniformity of size and shape.