MIL-P-14514G
AWS D1.1 Structural Welding Code - Steel
ASME Boiler and Pressure Vessel Code, Section, IX, Welding, and Brazing
Qualifications.
The Government reserves the right to require recertification of any welder or
welding operator to produce acceptable welds.
3.18.5 Bolted connections.
Boltholes shall be accurately formed and shall
have the burrs removed.
Washers or lockwashers shall be provided where
necessary.
Matching thread areas securing bolts conforming to SAE J429 or
capscrews shall be of sufficient strength to withstand the tensile strength of
the bolt. All fasteners shall be correctly torqued and shall have full thread
engagement.
Bolts shall protrude not more than 2 full threads.
4.
QUALITY ASSURANCE PROVISIONS.
4.1
Responsibility for Inspection.
Unless otherwise specified in the
contract or purchase `order, the contractor is responsible for the performance of
all inspection requirements as specified herein.
Except as otherwise specified
in the contract or purchase order, the contractor may use his own or any other
facilities suitable for the performance of the Inspection requirements specified
herein, unless disapproved by the Government.
The Government reserves the right
to perform any of the inpsections set forth in the specification where such
inspections are deemed necessary to assure supplies and services conform to
prescribed requirements.
4.1.1 Responsibility for compliance.
All items must meet all requirements of
sections 3 and 5.
The inspection set forth in this specification shall become a
part of the contractor's overall inspection system or quality program. The
absence of any inspection requirements in the specification shall not relieve
the contractor of the responsibility of assuring that all products or supplies
submitted to the Government for acceptance comply with all requirements of the
contract.
Sampling in quality conformance does not authorize submission of
known defective material, either indicated or actual , nor does it commit the
Government to acceptance of defective material.
4.1.2 Component and material inspection.
The contractor is responsible for
insuring that components and materials used are manufactured, examined, and
tested in accordance with referenced specifications and standards, as applicable.
Failure of any examination or test by the
4.1.3 Disassembly inspection.
first article model shall be cause for disassembly, in the presence of a
Government representative, of the first article model to the extent necessary to
Each disassembled part shall be examined in
determine the cause of failure.
detail for compliance with this specification and referenced drawings in regard
Parts not complying with
to materials, dimensions, tolerances, and workmanship.
such requirements shall be rejected and shall be cause for rejection of the
first article model,
Reassembly with replacement parts and retesting shall be
Government furnished property shall be
the responsibility of the contractor.
excluded from the requirements of this paragraph.