MIL-P-14514G
4.2 Classification of inspection.
The inspection requirements specified
herein are classified as follows:
First article inspection (see 4.3).
a.
b.
Quality conformance inpsection (see 4.4).
c.
Inspection comparison (see 4.6).
d.
Inspection of packaging (see 4.7).
4.3 First article inspection.
4.3.1 Examination.
the first article pump shall be examined for defects as
specified (see 4.5.1). Presence of one or more defects shall be cause for
rejection or for performing the disassembly inspection specified in 4.1.3.
4.3.2 Tests.
The first article pump shall be tested as specified in 4.5.2.
Failure of any tests shall be cause for rejection and for performing the
disassembly inspection specified in 4.1.3.
4.4
Quality conformance
inspection.
4.4.1
Sampling.
Sampling for examination shall be in accordance with
4.4.1.1 Examination.
MIL-STD-105, inspection level II.
Sampling for tests shall be in accordance with MIL-STD-105,
4.4.1.2 Tests.
inpsection level S-2.
Samples selected in accordance with 4.4.1 shall be
4.4.2 Examination.
examined for the defects specified in 4.5.1. AQL shall be 1.0 percent defective.
4.4.3
Tests.
4.4.3.1
individual.
Each pump shall be tested as specified in 4.5.2.1 and
4.4.3.1.1 Pump.
4.5.2.2.
Failure of this test shall be cause for rejection.
4.4.3.1.2 Fuel tank. The fuel tank of each type 11 pump shall be tested as
Failure of the test shall be cause for rejection.
specified in 4.5.2.3.
4.4.3.2 Samples.
Samples selected in accordance with 4.4.1 shall be tested
as specified in 4.5.2.10. AQL shall be 1.0 percent defective.
4.5 Inspection procedure.
The pump shall be examined as specified herein for the
4.5.1 Examination.
following defects: