MIL-P-14514G
tolerances within those prescribed on the drawings to insure correct fit,
assembly, and operation of the pumps.
Any data (e.g., shop drawings, layouts,
flow sheets, processing procedures, etc.) prepared by the contractor or obtained
from a vendor to support fabrication and manufacture of the production item
shall be made available, upon request, for inspection by the contracting officer
or his designated representative.
3.2 First article. Unless otherwise specified (see 6.2), a sample shall be
subjected to first article inspection (see 4.3 and 6.3). Any changes or
deviations of pumps from the approved first article during production will be
subject to the approval of the contracting officer.
Approval of the first
article will not relieve the contractor of his obligation to furnish pumps
conforming to this specification.
3.3 Material. Material shall be as specified herein and on the applicable
drawings.
Materials not specified shall be selected by the contractor and shall
be subject to all provisions of this specification.
3.3.1 Material deterioration prevention and control. The pump shall be
fabricated from compatible materials, inherently corrosion resistant or treated
to provide protection against the various forms of corrosion and deterioration
that may be encountered in any of the applicable operating and storage
environments to which the pump may be exposed.
Dissimilar metals shall not be used in intimate
3.3.2 Dissimilar metals.
Dissimilar
contact with each other unless protected against galvanic corrosion.
metals and methods of protection are defined and detailed in MIL-STD-889.
3.3.3 Identification of materials and finishes. The contractor shall
identify the specific material, material finish or treatment for use with
component and subcomponent, and shall make information available upon request to
the contracting officer or designated representative.
For the purpose of this requirement, recovered
3.3.4 Recovered materials.
materials are those materials which have been collected from solid waste and
reprocessed to become a source of raw materials, as distinguished from virgin
raw materials. The components, pieces and parts incorporated in the pump may be
newly fabricated from recovered materials to the maximum extent practicable,
provided the pump produced meets all other requirements of this specification.
Used, rebuilt or remanufactured components, pieces and parts shall not be
incorporated in the pump.
3.4
Threads.
Screw threads shall conform to FED-STD-H28.
3.5 Environmental conditions.
The pumps shall perform as specified herein in
3.5.1 Operating temperature.
any ambient temperature from +32 °F (0 °C) to +125 °F (52 °C), when tested in
accordance with 4.5.2.4 and 4.5.2.5.
The pumps shall not be damaged by storage in any
3.5.2 Storage temperature.
ambient temperature from +160 °F (71 °C) to 50 °F (-46 °C).