MIL-PRF-62495B(AT)
TABLE I. Classification of inspections.
First article
Conformance
Require-
Inspec-
Examin- Accept-
Title
ment
tion
PPI IPI
ation
ance
Materials and construction 3.2, 3.2.1,
4.6.1
X
X
3.3.2, 3.3.6
and 3.3.8
4.6.2
X
X
X
Defects (see 4.6.2 and
3.3, 3.3.1,
table II)
3.3.3, 3.3.4,
3.3.5 thru
3.3.8, 3.5
thru 3.7
Fluid output
3.4.1
4.6.3
X
X
X 1/
Relief valve
3.4.1.1
4.6.3.1
X
X
X
Leakage
3.4.1.2
4.6.3.2
X
X
X
Slope operation
3.4.2
4.6.4
X
X
X
Solenoid valve operation
3.4.3
4.6.5
X
X
X
EMI
3.4.4
4.6.6
X
X
X
Endurance
3.4.5
4.6.7
X
X
High temperature
3.4.6.1
4.6.8.1
X
X
Low temperature
3.4.6.2
4.6.8.2
X
X
Humidity
3.4.6.3
4.6.8.3
X
X
Steam and waterjet
3.4.6.4
4.6.8.4
X
X
cleaning
Shock
3.4.6.5
4.6.8.5
X
X
Vibration
3.4.6.6
4.6.8.6
X
X
Fungus resistance
3.4.6.7
4.6.8.7
X
X
Corrosion resistance
3.4.6.8
4.6.8.8
X
X
Sand and dust
3.4.6.9
4.6.8.9
X
X
1/ 100% testing for fluid output performance.
TABLE II. Classification of defects.
Method of
examination
Category
Defect
Critical
None
Major:
101
Nonconformance in design and construction (see 3.3).
Visual
102
Dimensions affecting interchangeability out of tolerance
SIE 1/
(see 3.3).
103
Faulty workmanship affecting performance (see 3.7).
Visual
11