3 5.9 3 Starting systems. The starting system for gasoline engines rated
10 hp and below may be manual (rope, crank, or recoil)
The starting system for
gasoline engines rated over 10 hp shall be electric. All diesel engines shall
have electric starting systems. Electric starting systems shall be 12 volts and
shall include an electric cranking motor, charging alternator, regulator,
dry-charged battery with cables, starter switch, and ammeter. Gasoline engines
with electric starting systems shall include a high tension, distributor-type
ignition system. Ether starting systems, if furnished for diesel engines, shall
be of the automatic injection engine temperature limited type, or controlled
from the control panel, and shall be inoperative with the engine running.
Engines rated over 30 hp shall be equipped with an hour
3.5.9.4 Hour meter.
meter. The meter shall either be electrical or mechanical and shall register
not less than 9,999.9 hours of operating time.
3.5.9.5 Air pollution control.
Pump engines shall comply with EPA 40, CFR,
Part 86 governing the control of air pollution from engines intended for
industrial application in effect on the date of manufacture.
3.6.1 Base mounting (classes 1 and 5).
Base mountings shall consist of a
flat steel plate or a steel plate or sheet formed to provide a raised horizontal
center section with supporting vertical sections along each longitudinal edge.
Base mountings consisting of a combination of steel channels, flat steel
runners , or other structural steel shapes will be acceptable. The base mounting
shall be of sufficient thickness and rigidity to maintain the pump and engine in
proper alignment under normal conditions of operation and transport. All class
1 base-mounted pumps shall be equipped with a lifting eye or a lifting bail.
Base-mounted size 5M, 5MT, and 5MTC class 1 pumps shall also be equipped with a
one-man closed grip carrying handle. The maximum net weight of size 5M and 5MT
shall be 85 lb. Base-mounted size 8M and 9MTC, class 1 pumps shall also be
equipped with a two-man closed grip carrying handle. The maximum net weight of
size 8M and 9MTC pumps shall be 170 lb. Class 5, base-mounted pumps shall be
furnished with a tubular, wrap-around, welded, roll-bar frame firmly attached to
the base mounting. The frame shall consist of tubular members having an outside
diameter of not less than 3/4-inch. The frame shall be designed to prevent
damage to any component of the pump unit should the pump roll on its top or any
of its four sides. In accordance with 1.2, base mountings shall be limited to
pumps having nominal capacities not greater than 9,000 gph for class 5, and not
greater than 18,000 gph for class 1.
3.6.2 Skid mounting (class 3). When specified (see 6.2), skid mountings
shall be furnished for pumps having nominal capacities of not less than
20,000 gph. The skid mounting shall consist of a base mounting having steel
skids longitudinal along each of the two longest edges of the base mounting.
The skids shall be structural steel shapes and shall be of sufficient depth to
provide not less than 3-inch clearance between the ground and the underside of
the base plate or cross members. The bearing surface of each skid shall be not
less than 2 inches wide. Both ends of each skid shall be beveled or rounded to
facilitate skidding and shall be equipped with pulling attachments. A hole, not