MIL-PRF-52109H
(180 degrees apart) of the pumping assembly, with both in the horizontal position.
a. Suction connection shall be 2-inch, female, quick-disconnect couplings and gaskets
IAW A-A-59326, Class A, fitted with tethered dust plugs IAW A-A-59326/11, Class A.
b. Discharge connection shall be 2-inch, male, quick-disconnect couplings IAW A-A-
59326, Class A, fitted with tethered dust caps and gaskets IAW A-A-59326/10, Class A.
3.4.3 Fuel compatibility. Except for Class 1 (EMD), the pumping assembly shall be
capable of operating on, all military and commercial kerosene based fuels conforming to, as a
minimum, those listed below without restrictions or kits. JP-8 shall be the designated primary
fuel for engine operation.
a.
MIL-DTL-83133 (JP-8) (NATO F-34) (see 6.4)
b.
MIL-DTL-5624 (JP-5) (NATO F-44) (see 6.4)
c.
A-A-52557 (Diesel-military, including NATO F-54) (see 6.4)
d.
ASTM-975 (Diesel-US commercial)
e.
MIL-DTL-83133 (NATO F-35) (see 6.4)
f.
ASTM-D 1655 (Jet A-1)
3.4.4 Dimensional and weight limits. The weight of the pumping assembly, with an
empty fuel tank and pump housing, shall not exceed 300 pounds.
3.4.4.1 Type I, Size 1. The pumping assembly, in its stored configuration, shall not
exceed 29.00 x 26.00 x 25.00 inches high.
3.4.4.2 Type I, Size 2. The pumping assembly, in its stored configuration, shall not
exceed 33.00 x 21.00 x 33.00 inches high.
3.4.4.3 Type II, Size 1, Class 1 (EMD). The pumping assembly, in its stored
configuration, shall not exceed 21.00 x 13.00 x 22.00 inches high.
3.4.4.4 Type II, Size 1, Class 2 (DED). The pumping assembly, in its stored
configuration, shall not exceed 30.00 x 25.00 x 30.00 inches high.
3.4.4.5 Type II, Size 2. The pumping assembly, in its stored configuration, shall not
exceed 37.00 x 27.00 x 31.00 inches high.
3.5 Ownership and support requirements.
3.5.1 Safety. All shafts or rotating parts shall be guarded when such parts are exposed to
contact with personnel or otherwise create a hazard. All hot surfaces of the equipment, including
exhaust components exposed to contact with personnel or that create a fire hazard, shall be fully
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business