MIL-PRF-62331A(AT)
TABLE I. Classification of defects.
Method of
Category
Defect
examination
Major:
SIE 1/
101
Dimensions affecting interchangeability not within
tolerances (see 3.3).
102
Metal not corrosion resistant or inadequately
Visual
corrosion protected (see 3.2.1).
103
Exposed nonfunctional parts inadequately painted
Visual
(see 3.2.1).
Fungistatic materials not furnished or properly
Visual
104
certified (see 3.2.2).
Minor:
201
SIE
Dimensions not affecting interchangeability not within
tolerances (see 3.3).
202
Visual
Improper marking (see 3.5).
203
Visual
Improper workmanship (see 3.6).
204
Visual
Pump not packaged as specified (see 5.1).
1/ SIE = Standard Inspection Equipment.
TABLE II. Classification of tests.
First
Conformance
Title
Requirement
Test
article
Acceptance (100%) Control
X
3.4.1
4.5.2
Voltage range
X
X
3.4.2
4.5.3
Current draw
X
X
3.4.3
4.5.4
Efficiency
X
X
3.4.4
4.5.5
Flow rate
X
X
3.4.5
4.5.6
Durability
X
X
3.4.6
4.5.7
Electromagnetic
interference
X
3.4.7
4.5.8
Dielectric strength
X
3.4.8
4.5.9
Insulation resistance
X
X
3.4.9
4.5.10
Dynamic balance
X
X
3.4.10
4.5.11
Temperature resistance
4.5.11.1
High
4.5.11.2
Low
X
4.5.12
Vibration resistance
3.4.11
X
4.5.12.1
Control
X
3.4.12
4.5.13
Shock resistance
X
4.5.13.1
Control
4.5.14
X
Corrosion resistance
3.4.13
4.5.15
X
Waterproofness
3.4.14
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business